GTB TZERO Implant System

The body, threading, design, and structure make GTB TZERO the best implant for immediate loading.

  • Outstanding results in post-extraction scenarios

  • Conical connection in the GTB implant system

  • High biological efficiency

  • Primary stability in any bone condition

  • No bacterial infiltration

  • Active apex designed for vertical under-preparations

Maximum Respect for Hard and Soft Tissues

GTB TZERO redefines the concept of biological respect, introducing innovation, simplicity, and versatility to a prosthetic system that has proven to be one of the most reliable and durable in Advan's history.

Modularity dedicated to safeguarding tissue health.

With GTB TZERO, simple and immediate decisions can be made during the surgical act to manage any anatomical condition

ADVAN

The morphology and connection stem from the idea of creating a system inspired by implantology literature and history, reinterpreting its core principles with full respect for biology. A single connection diameter for all prosthetic components

ADVAN

GTB TZERO is a dynamic implant optimized for immediate loading, providing high torque levels even in softer bone. It supports various solutions for a broad spectrum of procedures, including immediate loading and placement in narrow alveolar ridges.  

ADVAN

The entire GTB implant system follows simple and safe protocols aimed at delivering predictable surgical and prosthetic outcomes over time. The ATiM protocol ensures aesthetically flawless and biologically secure results.

GTB TZERO Implant Design

The ideal dental implant for preserving anatomical structures.

Cylindrical profile of the implant neck
Fluids discharge channel
Patented Bioplatform
Conical core profile of the implant
Surface treatment OsseoGRIP®
Double-Lead Threading with Progressive and Modified Reverse Buttress Design
Active apex for exceptional primary stability
ADVAN

The implant neck is designed without threads or micro-threads to ensure more efficient load transmission to the alveolar bone.

  • Engineered to minimize stress on marginal bone and facilitate the placement of subcrestal implant
  • Reduces invasiveness while helping maintain marginal bone levels
ADVAN

It distributes the blood clot evenly across the entire implant surface, enhancing the implant's osseointegration.

  • Reduces hydrostatic compression of the clot and minimizes postoperative swelling
  • The clot, the most effective osteoinductive factor, remains in full contact with the entire surface
ADVAN

A geometrically complex horizontal and vertical Platform Shifting creates ideal conditions for implant-abutment coupling and hard tissue stability.

  • Prosthetic mis-matching at the implant connection level
  • Increased soft tissue volume around the peri-implant area
  • Single diameter for all prosthetic components
  • Establishes a protected space for the clot, ensuring rapid coronal osseointegration
ADVAN

  • Reduced osteotomy
  • Ensures excellent primary stability without excessive compression of the surrounding bone
  • Allows for under-preparation in soft bone
ADVAN
Non-aggressive treatment of the implant surface: hydroxyapatite blasting followed by a washing process.


  • Enhances surface osteoconductivity for rapid bone regrowth and increased bone-to-implant contact (BIC)
  • The fully blasted Bioplatform promotes bone growth above the platform level
ADVAN
  • Ensures optimal distribution of masticatory forces
  • Provides excellent primary stability even in low-quality bone conditions
  • Suitable for immediate loading protocols
  • Features triangular and aggressive threads in the apical third of the implant, transitioning to trapezoidal threads in the coronal third
  • ADVAN

    • Possibility of also being able to perform vertical sub-preparations 
    • Increased tapping power of the implant
    • Excellent primary stability even in complex anatomical conditions
    • Possibility to easily perform bicortical techniques

    One of its kind: the exclusive Gingival Former Abutment 

    The GFA system is the exclusive prosthetic system patented by Advan for the GTB line that transforms the crestal or sub-crestal implant into a transmucosal implant.The same implant-abutment connection at tissue level, facilitating future prosthetic procedures.

    The unique GTB + GFA modular system

    The GTB + GFA modular system is today’s top choice for aesthetic single-tooth rehabilitation. It is the only intermediate component on the market designed to replicate a tissue-level sealing conical connection. With simple procedures, it guarantees optimal biological safety while preserving the peri-implant mucosal barrier. Featuring the One Time Abutment concept and a tissue-level prosthetic platform, it ensures effortless management with an exclusive component by Advan.

    Tissue-level prosthetics
    From bone level to tissue level
    Sub-crestal positioning

    • Simple and easy-to-perform prosthetic procedures
    • Designed for the restoration of single crowns and bridges
    • Suitable for cemented and screw-retained prosthetic rehabilitations

    • One Abutment One Time
    • Ensures a mucosal seal
    • Maximum preservation of soft tissue
    • Dual sterile conical connection guarantees mechanical strength and a tight conical seal, even at the mucosal level

    • Preservation of marginal bone tissue
    • Stability of peri-implant soft tissues
    • Protection of the peri-implant mucosal barrier

    The synergy between GTB and GFA has led to the development of the AtiM protocol

    This working protocol allows for simple and secure handling of complex anatomical situations, ensuring predictable long-term surgical and prosthetic results.

    Informative publications to delve into the technical specifics of the Advan GTB Tzero implant system